{"id":52758,"date":"2019-06-11T08:49:32","date_gmt":"2019-06-11T06:49:32","guid":{"rendered":"https:\/\/wpml.rechner-sensors.com\/rechners-level-probes-just-got-very-smart"},"modified":"2021-02-16T14:25:36","modified_gmt":"2021-02-16T13:25:36","slug":"rechners-level-probes-just-got-very-smart","status":"publish","type":"post","link":"https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart","title":{"rendered":"Rechner\u2019s level probes just got very smart!"},"content":{"rendered":"<p><strong>Do you use level probes for tank or hopper fill height control? Imagine if you could fit a probe, connect it, push one button, just once, and the whole set-up was done?<\/strong><\/p>\n<p>And what if the level feedback was then the same for <em>all<\/em> media?<br \/>\nIn addition, what if the evaluation amplifier was not separate, but included as well? Too good to be true? Well not any more now that Rechner\u2019s high performance KFX TrueLevel probes have been released.<\/p>\n<p>These new Rechner probes do include all of the integrated evaluation electronics within the high sealed probe G1\u201c mounted connection head. Furthermore, using Rechner\u2019s patented three electrode concept, each probe has a reference area which compensates for the dielectric constant of any media (even as low as \u2265 \u0190r 1.2) so there is just one setting required to commission any new probe.<br \/>\nIf preferred, there is also an EasyTeach by Wire (ETW) facility, for remote set-up and control of the installed probe.<\/p>\n<p>Its just too simple!<\/p>\n<p>Another benefit is that the <a href=\"https:\/\/stage.rechner-sensors.com\/en\/?s=KFX-1&amp;post_type=product&amp;type_aws=true&amp;id=1&amp;filter=1\">new KFX TrueLevel <\/a>devices are set-up with an empty container which provides a linear analogue output signal over the whole fill range, of any media, in either 4-20mA or 0-10 V DC depending on the model selected.<\/p>\n<p>Probe materials available are PTFE, PEEK or GFK which include of course high standard Food+Bev plus Pharma certified alternatives as required. With probe lengths of up to 2m most production applications can be easily catered for.<\/p>\n<p>&nbsp;<\/p>\n<p>The Rechner TrueLevel KFX probes are ideal for multiple production areas where different media are processed through one machine as no set-up adjustments are required between batch changes.<\/p>\n<p>All of these TrueLevel analogue probes also include a low level switched output within the reference area near to the probe tip. This provides a valuable and often essential low level alert for any tank or hopper control system.<\/p>\n<p>For your next fill height control application, especially for multi-media process systems, please do fit and benefit from Rechner\u2019s new KFX TrueLevel probes.<\/p>\n<p><strong><a href=\"https:\/\/stage.rechner-sensors.com\/en\/?s=KFX-1&amp;post_type=product&amp;type_aws=true&amp;id=1&amp;filter=1\">RECHNER\u2019S KFX TRUELEVEL<\/a><br \/>\nPROBE OVERVIEW<\/strong><\/p>\n<ul>\n<li>Proven Rechner expertise in level probe technology<\/li>\n<li>Simple installation + one single easy probe set-up<\/li>\n<li>Empty tank, hopper or vessel adjustment<\/li>\n<li>All evaluation electronics, fully integrated and sealed into the mounting head<\/li>\n<li>Automatic media compensation (\u2265 \u0190r 1.2)<\/li>\n<li>Rechner High Performance reliability and level detection accuracy<\/li>\n<li>Stable 4-20mA or 0-10V DC analogue output for direct system integration<\/li>\n<li>Wide 18-36V DC supply voltage + standard M12 international connection<\/li>\n<li>Certified FDA + Pharma probe materials<\/li>\n<li>Solid state electronics with no moving parts for long in-service life<\/li>\n<li>Large range of process fittings and mountings are available<\/li>\n<\/ul>\n<p>#KF0638<br \/>\n#KF0639<br \/>\n#KF0643<br \/>\n#KF0644<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Do you use level probes for tank or hopper fill height control? Imagine if you could fit a probe, connect it, push one button, just once, and the whole set-up was done? And what if the level feedback was then the same for all media? In addition, what if the evaluation amplifier was not separate, but included as well? Too good to be true? Well not any more now that Rechner\u2019s high performance KFX TrueLevel probes have been released. These new Rechner probes do include all of the integrated evaluation electronics within the high sealed probe G1\u201c mounted connection head. Furthermore, using Rechner\u2019s patented three electrode concept, each probe has a reference area which compensates for the dielectric constant of any media (even as low as \u2265 \u0190r 1.2) so there is just one setting required to commission any new probe. If preferred, there is also an EasyTeach by Wire (ETW) facility, for remote set-up and control of the installed probe. Its just too simple! Another benefit is that the new KFX TrueLevel devices are set-up with an empty container which provides a linear analogue output signal over the whole fill range, of any media, in either 4-20mA or 0-10 V DC depending on the model selected. Probe materials available are PTFE, PEEK or GFK which include of course high standard Food+Bev plus Pharma certified alternatives as required. With probe lengths of up to 2m most production applications can be easily catered for. &nbsp; The Rechner TrueLevel KFX probes are ideal for multiple production areas where different media are processed through one machine as no set-up adjustments are required between batch changes. All of these TrueLevel analogue probes also include a low level switched output within the reference area near to the probe tip. This provides a valuable and often essential low level alert for any tank or hopper control system. For your next fill height control application, especially for multi-media process systems, please do fit and benefit from Rechner\u2019s new KFX TrueLevel probes. RECHNER\u2019S KFX TRUELEVEL PROBE OVERVIEW Proven Rechner expertise in level probe technology Simple installation + one single easy probe set-up Empty tank, hopper or vessel adjustment All evaluation electronics, fully integrated and sealed into the mounting head Automatic media compensation (\u2265 \u0190r 1.2) Rechner High Performance reliability and level detection accuracy Stable 4-20mA or 0-10V DC analogue output for direct system integration Wide 18-36V DC supply voltage + standard M12 international connection Certified FDA + Pharma probe materials Solid state electronics with no moving parts for long in-service life Large range of process fittings and mountings are available #KF0638 #KF0639 #KF0643 #KF0644<\/p>\n","protected":false},"author":3,"featured_media":124419,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[1873],"tags":[],"class_list":["post-52758","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","entry","post-inner"],"acf":[],"cp_meta_data":{"_encloseme":["1"],"_wpml_media_featured":["1"],"_wpml_media_duplicate":["1"],"_qt_imported":["from-45903"],"_qt_links_fixed":["1"],"_yoast_wpseo_primary_category":[""],"_thumbnail_id":["124419"],"_last_translation_edit_mode":["translation-editor"]},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Rechner\u2019s level probes just got very smart! - Rechner Sensors<\/title>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Rechner\u2019s level probes just got very smart! - Rechner Sensors\" \/>\n<meta property=\"og:description\" content=\"Do you use level probes for tank or hopper fill height control? Imagine if you could fit a probe, connect it, push one button, just once, and the whole set-up was done? And what if the level feedback was then the same for all media? In addition, what if the evaluation amplifier was not separate, but included as well? Too good to be true? Well not any more now that Rechner\u2019s high performance KFX TrueLevel probes have been released. These new Rechner probes do include all of the integrated evaluation electronics within the high sealed probe G1\u201c mounted connection head. Furthermore, using Rechner\u2019s patented three electrode concept, each probe has a reference area which compensates for the dielectric constant of any media (even as low as \u2265 \u0190r 1.2) so there is just one setting required to commission any new probe. If preferred, there is also an EasyTeach by Wire (ETW) facility, for remote set-up and control of the installed probe. Its just too simple! Another benefit is that the new KFX TrueLevel devices are set-up with an empty container which provides a linear analogue output signal over the whole fill range, of any media, in either 4-20mA or 0-10 V DC depending on the model selected. Probe materials available are PTFE, PEEK or GFK which include of course high standard Food+Bev plus Pharma certified alternatives as required. With probe lengths of up to 2m most production applications can be easily catered for. &nbsp; The Rechner TrueLevel KFX probes are ideal for multiple production areas where different media are processed through one machine as no set-up adjustments are required between batch changes. All of these TrueLevel analogue probes also include a low level switched output within the reference area near to the probe tip. This provides a valuable and often essential low level alert for any tank or hopper control system. For your next fill height control application, especially for multi-media process systems, please do fit and benefit from Rechner\u2019s new KFX TrueLevel probes. RECHNER\u2019S KFX TRUELEVEL PROBE OVERVIEW Proven Rechner expertise in level probe technology Simple installation + one single easy probe set-up Empty tank, hopper or vessel adjustment All evaluation electronics, fully integrated and sealed into the mounting head Automatic media compensation (\u2265 \u0190r 1.2) Rechner High Performance reliability and level detection accuracy Stable 4-20mA or 0-10V DC analogue output for direct system integration Wide 18-36V DC supply voltage + standard M12 international connection Certified FDA + Pharma probe materials Solid state electronics with no moving parts for long in-service life Large range of process fittings and mountings are available #KF0638 #KF0639 #KF0643 #KF0644\" \/>\n<meta property=\"og:url\" content=\"https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart\" \/>\n<meta property=\"og:site_name\" content=\"Rechner Sensors\" \/>\n<meta property=\"article:published_time\" content=\"2019-06-11T06:49:32+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-02-16T13:25:36+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/stage.rechner-sensors.com\/wp-content\/uploads\/2019\/06\/KFX_Seite_Spiegelbild_KF0638_DSC09930-als-Smartobjekt-1_Q.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"3952\" \/>\n\t<meta property=\"og:image:height\" content=\"3952\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"D\u00e9sir\u00e9e Freeburn\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"D\u00e9sir\u00e9e Freeburn\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart#article\",\"isPartOf\":{\"@id\":\"https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart\"},\"author\":{\"name\":\"D\u00e9sir\u00e9e Freeburn\",\"@id\":\"https:\/\/stage.rechner-sensors.com\/en#\/schema\/person\/92677b77b80b0297facc32410a7baac7\"},\"headline\":\"Rechner\u2019s level probes just got very smart!\",\"datePublished\":\"2019-06-11T06:49:32+00:00\",\"dateModified\":\"2021-02-16T13:25:36+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart\"},\"wordCount\":446,\"commentCount\":0,\"image\":{\"@id\":\"https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart#primaryimage\"},\"thumbnailUrl\":\"https:\/\/stage.rechner-sensors.com\/wp-content\/uploads\/2019\/06\/KFX_Seite_Spiegelbild_KF0638_DSC09930-als-Smartobjekt-1_Q.jpg\",\"articleSection\":[\"News\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart\",\"url\":\"https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart\",\"name\":\"Rechner\u2019s level probes just got very smart! - Rechner Sensors\",\"isPartOf\":{\"@id\":\"https:\/\/stage.rechner-sensors.com\/en#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart#primaryimage\"},\"image\":{\"@id\":\"https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart#primaryimage\"},\"thumbnailUrl\":\"https:\/\/stage.rechner-sensors.com\/wp-content\/uploads\/2019\/06\/KFX_Seite_Spiegelbild_KF0638_DSC09930-als-Smartobjekt-1_Q.jpg\",\"datePublished\":\"2019-06-11T06:49:32+00:00\",\"dateModified\":\"2021-02-16T13:25:36+00:00\",\"author\":{\"@id\":\"https:\/\/stage.rechner-sensors.com\/en#\/schema\/person\/92677b77b80b0297facc32410a7baac7\"},\"breadcrumb\":{\"@id\":\"https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart#primaryimage\",\"url\":\"https:\/\/stage.rechner-sensors.com\/wp-content\/uploads\/2019\/06\/KFX_Seite_Spiegelbild_KF0638_DSC09930-als-Smartobjekt-1_Q.jpg\",\"contentUrl\":\"https:\/\/stage.rechner-sensors.com\/wp-content\/uploads\/2019\/06\/KFX_Seite_Spiegelbild_KF0638_DSC09930-als-Smartobjekt-1_Q.jpg\",\"width\":3952,\"height\":3952,\"caption\":\"rechner sensors KFX-1 KF0638 probe sonde smart\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Start\",\"item\":\"https:\/\/stage.rechner-sensors.com\/en\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Rechner\u2019s level probes just got very smart!\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/stage.rechner-sensors.com\/en#website\",\"url\":\"https:\/\/stage.rechner-sensors.com\/en\",\"name\":\"Rechner Sensors\",\"description\":\"[:de]Marktf\u00fchrer in kapazitiver Sensortechnologie und Qualit\u00e4t.[:en]Capacitive Sensors \u2013 for more than 50 years our special field.[:fr]Les capteurs capacitifs \u2013 depuis plus de 50 ans notre c\u0153ur de m\u00e9tier.[:es]Sensores capacitivos - desde m\u00e1s de 50 a\u00f1os nuestro campo de especialidad.[:it]Sensores capacitivos - desde m\u00e1s de 50 a\u00f1os nuestro campo de especialidad.[:]\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/stage.rechner-sensors.com\/en?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/stage.rechner-sensors.com\/en#\/schema\/person\/92677b77b80b0297facc32410a7baac7\",\"name\":\"D\u00e9sir\u00e9e Freeburn\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Rechner\u2019s level probes just got very smart! - Rechner Sensors","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"en_US","og_type":"article","og_title":"Rechner\u2019s level probes just got very smart! - Rechner Sensors","og_description":"Do you use level probes for tank or hopper fill height control? Imagine if you could fit a probe, connect it, push one button, just once, and the whole set-up was done? And what if the level feedback was then the same for all media? In addition, what if the evaluation amplifier was not separate, but included as well? Too good to be true? Well not any more now that Rechner\u2019s high performance KFX TrueLevel probes have been released. These new Rechner probes do include all of the integrated evaluation electronics within the high sealed probe G1\u201c mounted connection head. Furthermore, using Rechner\u2019s patented three electrode concept, each probe has a reference area which compensates for the dielectric constant of any media (even as low as \u2265 \u0190r 1.2) so there is just one setting required to commission any new probe. If preferred, there is also an EasyTeach by Wire (ETW) facility, for remote set-up and control of the installed probe. Its just too simple! Another benefit is that the new KFX TrueLevel devices are set-up with an empty container which provides a linear analogue output signal over the whole fill range, of any media, in either 4-20mA or 0-10 V DC depending on the model selected. Probe materials available are PTFE, PEEK or GFK which include of course high standard Food+Bev plus Pharma certified alternatives as required. With probe lengths of up to 2m most production applications can be easily catered for. &nbsp; The Rechner TrueLevel KFX probes are ideal for multiple production areas where different media are processed through one machine as no set-up adjustments are required between batch changes. All of these TrueLevel analogue probes also include a low level switched output within the reference area near to the probe tip. This provides a valuable and often essential low level alert for any tank or hopper control system. For your next fill height control application, especially for multi-media process systems, please do fit and benefit from Rechner\u2019s new KFX TrueLevel probes. RECHNER\u2019S KFX TRUELEVEL PROBE OVERVIEW Proven Rechner expertise in level probe technology Simple installation + one single easy probe set-up Empty tank, hopper or vessel adjustment All evaluation electronics, fully integrated and sealed into the mounting head Automatic media compensation (\u2265 \u0190r 1.2) Rechner High Performance reliability and level detection accuracy Stable 4-20mA or 0-10V DC analogue output for direct system integration Wide 18-36V DC supply voltage + standard M12 international connection Certified FDA + Pharma probe materials Solid state electronics with no moving parts for long in-service life Large range of process fittings and mountings are available #KF0638 #KF0639 #KF0643 #KF0644","og_url":"https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart","og_site_name":"Rechner Sensors","article_published_time":"2019-06-11T06:49:32+00:00","article_modified_time":"2021-02-16T13:25:36+00:00","og_image":[{"width":3952,"height":3952,"url":"https:\/\/stage.rechner-sensors.com\/wp-content\/uploads\/2019\/06\/KFX_Seite_Spiegelbild_KF0638_DSC09930-als-Smartobjekt-1_Q.jpg","type":"image\/jpeg"}],"author":"D\u00e9sir\u00e9e Freeburn","twitter_card":"summary_large_image","twitter_misc":{"Written by":"D\u00e9sir\u00e9e Freeburn","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart#article","isPartOf":{"@id":"https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart"},"author":{"name":"D\u00e9sir\u00e9e Freeburn","@id":"https:\/\/stage.rechner-sensors.com\/en#\/schema\/person\/92677b77b80b0297facc32410a7baac7"},"headline":"Rechner\u2019s level probes just got very smart!","datePublished":"2019-06-11T06:49:32+00:00","dateModified":"2021-02-16T13:25:36+00:00","mainEntityOfPage":{"@id":"https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart"},"wordCount":446,"commentCount":0,"image":{"@id":"https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart#primaryimage"},"thumbnailUrl":"https:\/\/stage.rechner-sensors.com\/wp-content\/uploads\/2019\/06\/KFX_Seite_Spiegelbild_KF0638_DSC09930-als-Smartobjekt-1_Q.jpg","articleSection":["News"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart#respond"]}]},{"@type":"WebPage","@id":"https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart","url":"https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart","name":"Rechner\u2019s level probes just got very smart! - Rechner Sensors","isPartOf":{"@id":"https:\/\/stage.rechner-sensors.com\/en#website"},"primaryImageOfPage":{"@id":"https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart#primaryimage"},"image":{"@id":"https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart#primaryimage"},"thumbnailUrl":"https:\/\/stage.rechner-sensors.com\/wp-content\/uploads\/2019\/06\/KFX_Seite_Spiegelbild_KF0638_DSC09930-als-Smartobjekt-1_Q.jpg","datePublished":"2019-06-11T06:49:32+00:00","dateModified":"2021-02-16T13:25:36+00:00","author":{"@id":"https:\/\/stage.rechner-sensors.com\/en#\/schema\/person\/92677b77b80b0297facc32410a7baac7"},"breadcrumb":{"@id":"https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart#primaryimage","url":"https:\/\/stage.rechner-sensors.com\/wp-content\/uploads\/2019\/06\/KFX_Seite_Spiegelbild_KF0638_DSC09930-als-Smartobjekt-1_Q.jpg","contentUrl":"https:\/\/stage.rechner-sensors.com\/wp-content\/uploads\/2019\/06\/KFX_Seite_Spiegelbild_KF0638_DSC09930-als-Smartobjekt-1_Q.jpg","width":3952,"height":3952,"caption":"rechner sensors KFX-1 KF0638 probe sonde smart"},{"@type":"BreadcrumbList","@id":"https:\/\/stage.rechner-sensors.com\/en\/rechners-level-probes-just-got-very-smart#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Start","item":"https:\/\/stage.rechner-sensors.com\/en"},{"@type":"ListItem","position":2,"name":"Rechner\u2019s level probes just got very smart!"}]},{"@type":"WebSite","@id":"https:\/\/stage.rechner-sensors.com\/en#website","url":"https:\/\/stage.rechner-sensors.com\/en","name":"Rechner Sensors","description":"[:de]Marktf\u00fchrer in kapazitiver Sensortechnologie und Qualit\u00e4t.[:en]Capacitive Sensors \u2013 for more than 50 years our special field.[:fr]Les capteurs capacitifs \u2013 depuis plus de 50 ans notre c\u0153ur de m\u00e9tier.[:es]Sensores capacitivos - desde m\u00e1s de 50 a\u00f1os nuestro campo de especialidad.[:it]Sensores capacitivos - desde m\u00e1s de 50 a\u00f1os nuestro campo de especialidad.[:]","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/stage.rechner-sensors.com\/en?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/stage.rechner-sensors.com\/en#\/schema\/person\/92677b77b80b0297facc32410a7baac7","name":"D\u00e9sir\u00e9e Freeburn"}]}},"_links":{"self":[{"href":"https:\/\/stage.rechner-sensors.com\/en\/wp-json\/wp\/v2\/posts\/52758","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/stage.rechner-sensors.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/stage.rechner-sensors.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/stage.rechner-sensors.com\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/stage.rechner-sensors.com\/en\/wp-json\/wp\/v2\/comments?post=52758"}],"version-history":[{"count":0,"href":"https:\/\/stage.rechner-sensors.com\/en\/wp-json\/wp\/v2\/posts\/52758\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/stage.rechner-sensors.com\/en\/wp-json\/wp\/v2\/media\/124419"}],"wp:attachment":[{"href":"https:\/\/stage.rechner-sensors.com\/en\/wp-json\/wp\/v2\/media?parent=52758"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/stage.rechner-sensors.com\/en\/wp-json\/wp\/v2\/categories?post=52758"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/stage.rechner-sensors.com\/en\/wp-json\/wp\/v2\/tags?post=52758"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}